        西門子中國代理6SL3210-1KE21-3AP1
        發布時間: 2023-02-15 12:16 更新時間: 2024-11-22 08:00
        觀看西門子中國代理6SL3210-1KE21-3AP1視頻

        西門子中國代理6SL3210-1KE21-3AP1

        我公司是西門子簽約代理商備有大量西門子產品潯之漫智控技術(上海)有限公司:西門子授權代理商

        現貨庫存;大量全新庫存,款到48小時發貨,無須漫長貨期

        西門子PLC(S7-200、S7-200 SMART、S7-300、S7-400、S7-1200、S7-1500、ET200S、ET200M、ET200SP)、觸摸屏、變頻器、工控機、電線電纜、儀器儀表等,產品選型、詢價、采購,敬請聯系,潯之漫智控技術(上海)有限公司 

        設計

        SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device.

        The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).

        SINAMICS G120C, frame size FSAA with BOP-2

        SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET, EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediately connected to PROFIBUS or PROFINET fieldbus systems without parameterization.

        Wireless commissioning, operation and diagnostics via mobile device or laptop thanks to the optional web server module SINAMICS G120 Smart Access enabling user-friendly operation and easy access to the converter, even if this is installed in areas difficult to access.

        SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs.

        SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.

        Line-side components

        Line filter

        SINAMICS G120C can be ordered with or without integrated Class A line filters. Optionally, an external Class B line filter can be used for classifying in a higher interference class.

        Line reactors

        Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter. A DC link reactor is integrated in frame sizes FSD to FSF, and therefore no line reactor is required.

        Recommended line-side overcurrent protection devices

        Overcurrent protection devices are absolutely necessary for the operation of the converters. The table listed in the section "Recommended line-side overcurrent protection devices" provides recommendations according to IEC and UL regulations, depending on the area of application. Recommendations on further overcurrent protection devices are available at:
        https://support.industry.siemens.com/cs/document/109750343

        More information about the listed Siemens fuses is available in Catalog LV 10 as well as in the Industry Mall.

        DC link components

        Braking resistors

        Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch). For the electromagnetically compatible connection of an optionally connectable braking resistor, the corresponding shield connection kit is to be ordered for frame sizes FSD to FSF.

        Load-side power components

        Output reactors

        Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.

        Supplementary system components

        IOP?2 Intelligent Operator Panel

        Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C.

        BOP?2 Basic Operator Panel

        A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled.

        Memory card

        The parameter settings for a converter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the converter has been replaced and the data have been downloaded from the memory card, the drive system is immediately ready for use again. The associated memory card holder is integrated in the converter.

        SINAMICS G120 Smart Access

        Wireless commissioning, operation and diagnostics via mobile device or laptop thanks to the optional web server module SINAMICS G120 Smart Access enabling user-friendly operation and easy access to the converter, even if this is installed in areas difficult to access.

        PC converter connection kit 2

        For controlling and commissioning a converter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC.

        Shield connection kits

        A shield connection kit is included in the scope of delivery for frame sizes FSAA to FSC.
        A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size for the frame sizes FSD to FSF. For the electromagnetically compatible connection of an optionally connectable braking resistor, the corresponding shield connection kit is to be ordered for frame sizes FSD to FSF.